Nurhalimah, Nurhalimah (2017) Perbandingan distribusi dosis berkas Elektron 12 MeV dengan menggunakan simulasi Monte Carlo-EGSnrc dan Analytical Anisotropic Algorithm (AAA). Diploma thesis, UIN Sunan Gunung Djati Bandung.
|
Text (COVER)
1_Cover.pdf Download (87kB) | Preview |
|
|
Text (ABSTRAK)
2_abstrak.pdf Download (49kB) | Preview |
|
|
Text (DAFTAR ISI)
3_daftarisi.pdf Download (56kB) | Preview |
|
|
Text (BAB I)
4_bab1.pdf Download (211kB) | Preview |
|
Text (BAB II)
5_bab2.pdf Restricted to Registered users only Download (820kB) | Request a copy |
||
Text (BAB III)
6_bab3.pdf Restricted to Registered users only Download (336kB) | Request a copy |
||
Text (BAB IV)
7_bab4.pdf Restricted to Registered users only Download (204kB) | Request a copy |
||
Text (BAB V)
8_bab5.pdf Restricted to Registered users only Download (54kB) | Request a copy |
||
|
Text (DAFTAR PUSTAKA)
9_daftarpustaka.pdf Download (182kB) | Preview |
Abstract
Telah dilakukan penelitian yang bertujuan membandingkan distribusi dosis berkas elektron 12 MeV hasil perhitungan TPS-Eclipse (AAA) dengan hasil simulasi Monte Carlo-EGSnrc. Simulasi Monte Carlo dilakukan dengan variasi field size dan variasi energi, penyinaran berkas elektron dilakukan pada phantom air berukuran 40x40x40 cm3 dengan SSD 100 cm. Pada perbandingan dengan variasi field size (10x10 cm2, 15x15 cm2, 20x20 cm2, dan 40x40 cm2) diketahui bahwa hasil TPS-Eclipse (AAA) energi berkas elektron 12 MeV yang paling mendekati hasil simulasi Monte Carlo adalah pada field size 10x10 cm2 dengan deviasi 0.06 %. Selanjutnya perbandingan variasi energi (12 MeV, 13 MeV, 14 MeV, 15 MeV, dan 18 MeV) field size 10x10 cm2 hasil simulasi Monte Carlo dengan hasil TPS-Eclipse (AAA) energi 12 MeV field size 10x10 cm2 didapatkan bahwa hasil TPS-Eclipse (AAA) terverifikasi dan hasil simulasi Monte Carlo tervalidasi pada energi 13 MeV untuk field size 10x10 cm2 (deviasi 0.059 %). Oleh karena itu, hasil simulasi Monte Carlo energi berkas elektron 13 MeV untuk field size 10x10 cm2 dapat dijadikan sebagai data pembanding pada treatment planning terhadap pasien. ABSTRACT A study was conducted to compare the dose distribution of 12 MeV electron beam of TPS-Eclipse (AAA) calculation with Monte Carlo-EGSnrc simulation result. Monte Carlo simulation is done with variation of field size and energy variation, electron beam irradiation done on phantom water size 40x40x40 cm3 with 100 cm SSD. In comparison with the variation of field size (10x10 cm2, 15x15 cm2, 20x20 cm2, and 40x40 cm2) it is known that the result of TPS-Eclipse (AAA) 12 MeV electron beam energy closest to Monte Carlo simulation result is in 10x10 cm2 size field with deviation 0.06 %. Furthermore, the comparison of energy variation (12 MeV, 13 MeV, 14 MeV, 15 MeV, and 18 MeV) field size 10x10 cm2 Monte Carlo simulation results with TPS-Eclipse (AAA) energy yield 12 MeV field size 10x10 cm2 found that TPS-Eclipse (AAA) verified and Monte Carlo simulation results validated at 13 MeV for field size 10x10 cm2 (deviation 0.059%). Therefore, the Monte Carlo simulation result of the electron beam energy of 13 MeV for the 10x10 cm2 size field can be used as comparison data on treatment planning for the patient.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Monte Carlo-EGSnrc; TPS-Eclipse (AAA); field siz; energi; treatment planning; distribusi dosis; berkas elektron. |
Subjects: | Medicine and Health > Medical Physics |
Divisions: | Fakultas Sains dan Teknologi > Program Studi Fisika |
Depositing User: | mrs nur halimah |
Date Deposited: | 20 Sep 2018 07:50 |
Last Modified: | 20 Sep 2018 07:50 |
URI: | https://digilib.uinsgd.ac.id/id/eprint/8590 |
Actions (login required)
View Item |